Honeywell FC-SCNT01 51454926-176 S300 Safety Controller Module in stock

Honeywell FC-SCNT01 51454926-176 is the main safety logic solver for Honeywell Safety Manager SC S300 SIS system.
Send Inquiry

Products Description

Honeywell FC-SCNT01 51454926-176 S300 Safety Controller Module in stock


Honeywell FC-SCNT01 (P/N 51454926-176) is the main safety logic solver for Honeywell Safety Manager SC S300 SIS system. It adopts QMR 2oo4D fault-tolerant architecture, certified SIL3 by TÜV to execute safety interlock and ESD logic for high-risk process plants.



Honeywell   FC-SCNT01 51454926-176 (1).jpeg

This hot-swappable controller supports redundant safety Ethernet communication and connects with FC-PUIO01 safety I/O modules via backplane bus. It is widely used as spare replacement for refinery, gas turbine and chemical ESD safety cabinets.


Honeywell   FC-SCNT01 51454926-176 (5).jpeg

Data Parameters


  • 1. Brand: Honeywell.

  • 2. Model: FC-SCNT01, Part No: 51454926-176.

  • 3. Product Type: S300 SIL3 Safety Main Controller.

  • 4. Application: Safety Manager SC S300 SIS safety instrument system.

  • 5. Feature: QMR 2oo4D architecture, SIL3, redundant safety Ethernet, hot swap.

  • 6. Characteristic: TÜV SIL3 certified, ATEX / IECEx compliant, comprehensive self-test.

  • 7. Communication: Safety backplane bus, Modbus TCP, safety Ethernet for BPCS interconnection.

  • 8. Package: Complete controller module with front status indicator panel.

  • 9. Mounting: S300 safety rack slot installation inside SIS cabinet.

  • 10. Operating Temperature: -40℃ ~ +70℃.

Core Functions


  • 1. Run safety logic program to implement emergency shutdown, burner management and safety interlock.

  • 2. Read field signal data from FC-PUIO01 I/O modules and output trip commands reliably.

  • 3. QMR fault tolerance ensures safety function continues even with internal single hardware failure.

  • 4. Exchange alarm and diagnostic data with Experion PKS DCS through redundant Ethernet.

  • 5. Record safety events and fault logs for safety audit, troubleshooting and maintenance.

Application Scenarios


  • 1. Petrochemical plant SIS ESD safety cabinet spare replacement and maintenance.

  • 2. Oil refinery and natural gas processing safety interlock renovation project.

  • 3. Gas turbine, boiler and offshore platform safety control system cabinet.

  • 4. Old Honeywell Safety Manager SC S300 safety rack upgrade and transformation.

  • 5. Hazardous chemical factory SIL3 safety instrument system spare inventory backup.

FAQ


  • 1. Q: What is Honeywell FC-SCNT01 51454926-176?
        A: It is the SIL3 main safety controller for Honeywell S300 Safety Manager SC SIS system.

  • 2. Q: What I/O module does it match?
        A: It works with FC-PUIO01 universal safety I/O module and FC-TUIO011 terminal base.

  • 3. Q: Is it compatible with Experion C300 DCS controller?
        A: It belongs to SIS safety controller, can communicate with C300 but cannot replace DCS CPU.


Leave Your Message