HIMA 80105 984080105 HIMatrix Safety Power Supply Module in stock

HIMA 80105, part number 984080105, is a SIL3 certified safety power supply module for HIMA HIMatrix safety controller system.
Send Inquiry

Products Description

HIMA 80105 984080105 HIMatrix Safety Power Supply Module in stock


HIMA 80105, part number 984080105, is a SIL3 certified safety power supply module for HIMA HIMatrix safety controller system. It converts 24VDC input into stable regulated internal supply voltage for HIMatrix CPU, I/O and communication modules, designed for safety instrumented systems in hazardous industrial sites.


HIMA  80105 984080105(3).jpeg

This module supports continuous power monitoring and fault diagnosis, with high efficiency and built-in relay alarm contact for power failure warning. It fits compactly into HIMatrix rack chassis. Widely used in power, chemical and pulp & paper SIS maintenance, spare replacement and safety system retrofit projects.


HIMA  80105 984080105(8).jpeg

HIMA  80105 984080105(1).jpeg

Data Parameters


  • 1. Brand: HIMA (Germany).

  • 2. Model: 80105, Part No:984080105.

  • 3. Product Type: Safety Power Supply Module.

  • 4. Application: HIMatrix SIS safety control system, SIL3 safety loop.

  • 5. Feature: SIL3 certification, integrated power diagnostic & alarm relay.

  • 6. Characteristic: 24VDC input, high efficiency >85%, ATEX Zone2 compliant.

  • 7. Alarm Relay Rating: 30VDC, 1A contact output.

  • 8. Package: DIN rack plug-in power module.

  • 9. Mounting: Installed inside HIMatrix safety controller chassis.

  • 10. Operating Temperature: -20℃ ~ +60℃.

Core Functions


  • 1. Convert external 24VDC power into stable regulated power for HIMatrix CPU and I/O modules.

  • 2. Continuous real-time monitoring of output voltage and internal hardware health status.

  • 3. Trigger dry contact alarm signal once power abnormality or internal fault occurs.

  • 4. Built-in overvoltage, overcurrent and short-circuit protection to protect the whole safety rack.

  • 5. TÜV SIL3 certification to guarantee power integrity for safety instrumented functions.

Application Scenarios


  • 1. Power plant SIS safety system HIMatrix rack power supply spare replacement.

  • 2. Petrochemical plant reactor safety interlock cabinet maintenance project.

  • 3. Pulp and paper mill boiler emergency shutdown safety control upgrade.

  • 4. Heavy industry SIL3 safety instrumented system spare parts inventory backup.

  • 5. Old HIMatrix safety power module renewal and retrofit project.

FAQ


  • 1. Q: What is HIMA 80105 984080105?
        A: It is SIL3 certified safety power supply module for HIMA HIMatrix safety instrumented system.

  • 2. Q: What safety level can it meet?
        A: TÜV certified SIL3, suitable for emergency shutdown and safety interlock loops.

  • 3. Q: Can it be hot swapped?
        A: Cut off the rack 24V supply before replacement; hot swap is forbidden for safety SIS rack.